AOTG30LBTA4 (Outdoor) & Compatible Indoor Units (Multi-Split)
This article provides the technical specifications for the General Airstage AOTG30LBTA4 outdoor unit and the compatible indoor units used in a four-room multi-split matched system.
MANUAL 1
MANUAL 2
Quick Answer
- What is the cooling capacity? AOTG30LBTA4 cooling capacity is 8.0 kW.
- What is the heating capacity? AOTG30LBTA4 heating capacity is 9.6 kW.
- What is the EER? AOTG30LBTA4 EER is 3.60 kW/kW (cooling).
- What is the COP? AOTG30LBTA4 COP is 4.00 kW/kW (heating).
- What power supply is required? Single phase, 240 V, 50 Hz.
- What refrigerant is used? R410A.
- What is the outdoor unit size? Dimensions (H × W × D): 830 × 900 × 330 mm.
- What is the maximum total pipe length? 70 m.
Model Mapping
- Outdoor unit model: AOTG30LBTA4
- Indoor unit model: Multiple compatible indoor units (four-room multi-split system)
- System type: Four room multi inverter
Electrical Specifications
- Power supply: Single phase
- Voltage: 240 V
- Frequency: 50 Hz
Cooling Performance (AOTG30LBTA4)
- Cooling capacity: 8.0 kW
- Power consumption (cooling): 2.22 kW
- Energy Efficiency Ratio (EER): 3.60 kW/kW
- Rated operating current (cooling): 9.3 A
Quick Answer (EER): The EER of AOTG30LBTA4 is 3.60 kW/kW.
Heating Performance (AOTG30LBTA4)
- Heating capacity: 9.6 kW
- Power consumption (heating): 2.40 kW
- Coefficient of Performance (COP): 4.00 kW/kW
- Rated operating current (heating): 10.1 A
Compressor & Refrigerant Details
Compressor
- Compressor type: Hermetic type, inverter
- Motor configuration: 4 poles, 3-phase, DC motor
- Compressor design: Twin rotary
- Compressor model: TNB220FPBMT
- Compressor weight: 14.3 kg (including oil)
Refrigerant
- Refrigerant type: R410A
- Precharged refrigerant (standard): 2,800 g
- Factory charge by total pipe length (FULL CHARGE):
- 2,800 g (50 m total piping)
- 3,050 g (60 m total piping)
- 3,300 g (70 m total piping)
- Additional charge rate: 25 g per meter
Piping Limits
- Maximum pipe length (total): 70 m
- Maximum pipe length (each indoor unit): 25 m
- Minimum pipe length (each indoor unit): 5 m
- Minimum pipe length (total): 20 m
- Maximum elevation (between indoor units): 10 m
- Maximum elevation (between indoor and outdoor units): 15 m
Fan Motor, Speed & Airflow (Outdoor Unit)
Fan Motor
- Outdoor unit fan motor: MFE-60TVT
Fan Speed
- Cooling: 820 rpm
- Heating: 780 rpm
Airflow
- Outdoor airflow (high): 3,300 m³/hr
Noise Levels (Outdoor Unit)
- Cooling: 50 dB
- Heating: 51 dB
Dimensions & Weight
Outdoor Unit (AOTG30LBTA4)
- Dimensions (H × W × D): 830 × 900 × 330 mm
- Weight: 68 kg (net) / 75 kg (shipping)
Notes for Support Teams
- This is a four-room multi-split outdoor unit designed to operate with multiple compatible indoor unit models.
- When answering “Does this support X meters of pipe?”, confirm both:
- Total pipe length (system total) limit: 70 m
- Per indoor unit pipe length limit: 25 m
- When answering “How much refrigerant is required?”, confirm:
- Base precharge: 2,800 g
- Additional charge: 25 g/m (apply per installation total beyond the precharged allowance, per service procedure)