General Assist Technical Reference

VRF II Indoor Unit Compatibility and Line-up

AJT040LCLAH / AJT045LCLAH / AJT054LCLAH
Outdoor and indoor unit line-up reference for 4 HP, 5 HP and 6 HP VRF II systems.
Use this article to: identify the outdoor unit capacity, maximum number of connectable indoor units, and the indoor unit models shown in the original product line-up.

1. Outdoor unit line-up

The outdoor unit range is shown from 4 HP to 6 HP in 1 HP increments.

HPCapacityOutdoor modelMaximum connectable indoor units
4 HP12.1 kWAJT040LCLAH7
5 HP14.0 kWAJT045LCLAH8
6 HP15.1 kWAJT054LCLAH8

Outdoor model designation

Code sectionMeaning shown in source
AJType: Outdoor unit
TDestination: FUJITSU
040 / 045 / 054Model code: 12.1 / 14.0 / 15.1 kW
LFunction: Inverter (R410A)
CLAModel change code
HSeries name: VRF II

2. Cassette indoor units

The source shows indoor unit capacities from 2.2 kW to 14.0 kW. A check mark indicates that a model type is shown as available for that capacity.

kWCodeCompact CassetteCassetteCircular Flow Cassette
XDXAXMXK
2.207
2.809
3.612
4.514
5.618
7.124
9.030
10.034
11.236
12.545
14.054

Cassette model list

TypeModels shown
Compact CassetteAUXB07GALH, AUXB09GALH, AUXB12GALH, AUXB14GALH, AUXB18GALH, AUXB24GALH
Cassette – XDAUXD18GALH, AUXD24GALH
Cassette – XAAUXA18GALH, AUXA24GALH, AUXA30GALH, AUXA34GALH, AUXA36GALH, AUXA45GALH, AUXA54GALH
Circular Flow Cassette – XMAUXM018GLAH, AUXM024GLAH, AUXM030GLAH
Circular Flow Cassette – XKAUXK018GLAH, AUXK024GLAH, AUXK030GLAH, AUXK034GLAH, AUXK036GLAH, AUXK045GLAH, AUXK054GLAH

3. Ducted indoor units

kWCodeLow Static Duct / Concealed FloorMini DuctSlim Duct / Slim Concealed FloorLow Static Pressure DuctMedium Static Pressure DuctHigh Static Pressure Duct
GCGAGBGAGBGA
2.207
2.809
3.612
4.514
5.618
7.124
9.030
10.034No indoor unit type marked in source table
11.236
12.545
14.054No indoor unit type marked in source table

Ducted model list

TypeModels shown
Low Static Pressure Duct / Concealed FloorARXB07GALH, ARXB09GALH, ARXB12GALH, ARXB14GALH, ARXB18GALH
Mini Duct – GCARXK07GCLH, ARXK09GCLH, ARXK12GCLH, ARXK14GCLH, ARXK18GCLH, ARXK24GCLH
Mini Duct – GAARXK07GALH, ARXK09GALH, ARXK12GALH, ARXK14GALH, ARXK18GALH, ARXK24GALH
Slim Duct / Slim Concealed FloorARXD07GALH, ARXD09GALH, ARXD12GALH, ARXD14GALH, ARXD18GALH, ARXD24GALH
Low Static Pressure DuctARXB24GALH, ARXB30GALH, ARXB36GALH, ARXB45GALH
Medium Static Pressure Duct – GBARXA24GBLH, ARXA30GBLH, ARXA36GBLH, ARXA45GBLH
Medium Static Pressure Duct – GAARXA24GALH, ARXA30GALH, ARXA36GALH, ARXA45GALH
High Static Pressure DuctARXC36GATH, ARXC36GBTH, ARXC45GATH

4. Floor, ceiling and compact floor indoor units

kWCodeFloor / CeilingCeilingCompact FloorCompact Floor (EEV external)
2.207
2.809
3.612
4.514
5.618
7.124
9.030
10.034No indoor unit type marked in source table
11.236
12.545
14.054

Floor and ceiling model list

TypeModels shown
Floor / CeilingABYA12GATH, ABYA14GATH, ABYA18GATH, ABYA24GATH
CeilingABYA30GATH, ABYA36GATH, ABYA45GATH, ABYA54GATH
Compact FloorAGYA007GCAH, AGYA009GCAH, AGYA012GCAH, AGYA014GCAH
Compact Floor – external EEVAGYE007GCAH, AGYE009GCAH, AGYE012GCAH, AGYE014GCAH

5. Wall-mounted indoor units

kWCodeWall MountedWall Mounted – external EEV
GTGCGBGAGTGCGA
2.207
2.809
3.612
4.514
5.618
7.124
9.030
10.034
11.236No wall-mounted type marked in source table
12.545No wall-mounted type marked in source table
14.054No wall-mounted type marked in source table

Wall-mounted model list

TypeModels shown
Wall MountedASYA07GACH, ASYA09GACH, ASYA12GACH, ASYA14GACH, ASYA007GTAH, ASYA009GTAH, ASYA012GCAH, ASYA014GCAH, ASYA18GBCH, ASYA24GBCH, ASYA18GACH, ASYA24GACH, ASYA30GACH, ASYA030GTAH, ASYA034GTAH
Wall Mounted – external EEVASYE07GACH, ASYE09GACH, ASYE12GACH, ASYE14GACH, ASYE007GTAH, ASYE009GTAH, ASYE012GCAH, ASYE014GCAH
Important: This article reproduces the model line-up shown in the supplied source document. Use the applicable design, installation and service documentation when confirming an actual system combination or replacement.