1. Background and Development Concept

The Fujitsu General VR-II Touch Wall Controller was developed to provide a user-friendly, visually intuitive interface that simplifies operation, enhances energy efficiency, and supports easy installation and maintenance.

It was designed with three key stakeholders in mind:

UserInstallerService Personnel
• Easy operability  
• Energy-saving features
• Modern decorative design
• Simplified wiring and setup  
• Fewer limitations
• Lower installation cost
• Quick error recognition  
• Easy access to diagnostic data
• Error history retention

This aligns with growing environmental regulations, increased energy-conscious behavior, and building management integration requirements


2. Product Overview

Core Characteristics

  • Touch-panel interface with wide LCD display

  • Multi-function operation through intuitive icons and menus

  • Energy management and control logic

  • Simplified installation via non-polar wiring

  • Integrated diagnostics and maintenance menus

The design emphasizes aesthetic appeal and intuitive usability, fitting seamlessly into office, hotel, and institutional interiors.


3. Energy-Saving Control Functions

The controller introduces four key automatic control features to reduce energy consumption and prevent operational waste:

FunctionDescriptionTypical Application
1. Auto-Off TimerAutomatically turns the indoor unit off after a preset duration (30–240 minutes).Meeting rooms, changing rooms, or offices where users may forget to shut down systems.
2. Set Temperature Auto ReturnAutomatically reverts the temperature to a predefined setting after a set period (10–120 minutes).Office environments to prevent users from keeping extreme settings.
3. Upper & Lower Temperature LimitsRestricts adjustable temperature range per mode (e.g., 18–30 °C cooling / 10–25 °C heating).Restaurants, classrooms, or areas requiring controlled comfort limits.
4. Weekly TimerTwo programmable schedules with up to eight change points per day. Controls On/Off, temperature, and mode by weekday.Offices, schools, and retail applications.

These automated functions ensure consistent comfort while maintaining operational efficiency.


4. Convenience Features

Designed for diverse applications—from commercial offices to hospitality—the new wired controller includes multiple user-convenience functions:

FunctionDescription
Anti-Cool / Anti-Heat ModeAutomatically starts cooling or heating when room temperature exceeds or drops below preset limits—even when the unit is off. Ideal for hotels or unoccupied rooms.
Summer Time DisplayAdjusts all time-based schedules automatically when daylight saving changes occur—no manual updates required.
Child LockPrevents accidental or unauthorized adjustments; activated by holding the On/Off button and screen for 4 seconds. Suitable for public or educational spaces.
Room Temperature DisplayBuilt-in temperature sensor shows real-time room temperature. (Avoid direct sunlight or airflow exposure.)
Status & Limitation DisplayClearly indicates control restrictions imposed by external systems (e.g., On/Off lock, mode lock).
Multi-Language SupportInterface available in 7 languages, supporting international installations.

These enhancements significantly improve usability and transparency, particularly for buildings managed under BMS control.


5. Operational Control Functions

The controller also supports enhanced administrative control features:

FunctionPurpose
Password ProtectionLocks access to system or energy-saving settings to prevent unauthorized changes. Commonly used in public facilities or server rooms.
Name RegistrationIndoor units can be individually named (e.g., “Meeting Room 1” or “Lobby AC”) for quick identification on the display. Especially useful in multi-zone installations.

These features allow facility managers to maintain standardized control parameters while enabling local flexibility.


6. Simplified Installation

The VR-II wired controller is designed for fast, error-free installation, reducing commissioning time.

ImprovementDescription
1. Non-Polar 2-Wire ConnectionReplaces the 3-wire system from older models, enabling connection without polarity concerns. Compatible wire thickness: AWG16–22 (1.3–0.3 mm²).
2. Multiple Cable Pass-Through OptionsWiring can enter from the rear or top; additional cable holes improve layout flexibility.
3. Auto Addressing & Location ConfirmationAutomatically assigns addresses to connected indoor units. Installers can confirm connection by using temporary louver motion or other display indicators.

This approach minimizes wiring errors and installation time compared to legacy rotary-switch setups


7. Maintenance & Service Functions

The new touch wall controller doubles as a service tool, allowing quick diagnostics directly from the interface:

FunctionDescription
Error History StorageSaves up to 32 historical errors for review. Data retained during power failure (if enabled via DIP switch).
Sensor & EEV MonitoringDisplays inlet/outlet heat exchanger temperatures (TH21–TH23) and EEV pulse degree for live performance evaluation.
Indoor Unit Model DisplayShows the model number of the connected indoor unit when an error occurs, simplifying field service and part replacement.

This eliminates the need for separate diagnostic equipment in many troubleshooting scenarios.


8. Technical Highlights

  • Power Supply: DC 12V via indoor unit communication line

  • Communication: Non-polar 2-wire system (dedicated signal bus)

  • Compatibility: VR-II / V-II / J-II indoor units (with feature differences)

  • Display: Wide monochrome touch LCD with LED backlight

  • Mounting: Standard wall-mount configuration with surface or recessed wiring options


9. Summary and Benefits

Key Advantages of the VR-II Touch Wall Controller

  • Intuitive touch-based user interface with enhanced visuals.

  • Advanced energy-saving automation for commercial environments.

  • Simplified installation using non-polar wiring and auto addressing.

  • Integrated error logging and sensor monitoring for service teams.

  • Multi-language, password-protected operation for flexible deployment in varied facility types.

Ideal Applications

  • Office complexes

  • Schools and public facilities

  • Hotels and hospitality environments

  • Commercial and retail establishments